The IRC (US residential code) allows a 7 3/4 in riser at most; your local code governs. At a 7 in target, a 44 in deck takes 7 risers and 6 treads.

Ground to the top of the deck boards

7 in is comfortable; the IRC allows up to 7 3/4

Nose to nose

How far each tread overhangs

Sets the tread thickness and the stringer spacing

Usually 16 in for 2x treads; DCA 6 allows 18 at most

1/8 to 3/8 in

Each board is cut into pieces as wide as the stair

Steps

7risers · 6 treads

6 5/16 in each (6.286 in); the deck is the top step

Stringers · 8 ft 2x12

4stringers

Stringer length 76.8 in (19.2 in to spare); total run 63 in; 30.9°

Boards · 12 ft

3boards

12 pieces of 36 in, 2 per step

Order 4 stringers of 8 ft 2x12 and 3 tread boards of 12 ft.

Check before you build

  • Open risers leave a 4.79 in gap on a rise over 30 in: close the risers or add a riser board; check your local building code.
  • Cut the bottom riser to 4 13/16 in (one tread thickness shorter).
  • 2R + T = 23.1 in (24 to 25 in feels natural).
  • Wood left under each notch: 5.9 in.

Plan for 6 ft 8 in of headroom, a solid landing 36 in deep at the foot and a handrail at 4 or more risers; check your local building code.

This estimates quantities, not structural design or code compliance. Check your local building code.

Stair stringer layout: how to lay out the notches and cuts

Mark each notch from the exact rise and run in the result: this picture is to scale on screen only, with rounded fractions.

Stringer board length for this stair: at least 76.8 in.

Stair stringer layout for your stair, one stringer seen from the side
44 inDeck63 inGround4 13/16Rise 6 5/16Run 10 1/25.86 in

One 8 ft 2x12 cut for 7 risers of 6 5/16 in and 6 treads of 10 1/2 in run, the bottom riser cut to 4 13/16 in, 5.86 in of wood left under each notch.

  • Cut one stringer, test-fit it, then trace it onto the rest. Stop each cut at the line: overcutting weakens it.
  • AWC DCA 6 shows 5 in at least under each notch.
  • Hangers for the rim are a design question for your plans.
  • A footing or pad at the foot needs digging: call 811 first.

A deck 44 in high takes 7 risers of 6 5/16 in and 6 treads: 4 stringers cut from 8 ft 2x12s and 3 tread boards of 12 ft.

How to use the stair calculator

  1. Measure the total rise: from the ground or landing where the bottom step will sit, straight up to the top of the deck boards. Measure at that spot, since the ground often slopes away from the deck.
  2. Set a riser target. 7 in is comfortable to walk; the IRC allows up to 7 3/4 in. The calculator never makes a riser taller than your target.
  3. Type the run per step, measured nose to nose (10.5 in is common), the nosing that hangs past each riser, and the stair width.
  4. Pick the treads: wood 2x6, wood 5/4x6 or composite. The choice sets the tread thickness and the stringer spacing. Composite spacing varies by brand: check its guide and change it if it says less.
  5. Read the three tags and the order line, check any warning under them, then print the slip or copy it.

How the stair calculator works

Risers. The total rise is divided by your riser target and rounded up. Every riser is then the same height: the rise divided by the number of risers. The result shows each riser to the nearest 1/16 in and to three decimals. Mark the stringer with the decimal if you can, because rounding each mark adds up over a flight, and the IRC lets risers differ by 3/8 in at most.

Treads. The deck surface is the top step, so a stair has one tread fewer than risers. The total run is the number of treads times the run per step.

Stringer length. A stringer runs along the line through the tread noses: the long side of a right triangle whose other sides are the rise and the total run. The calculator picks the shortest 2x12 of 8, 10, 12, 14 or 16 ft that covers it and shows the inches left over. It adds nothing for the end cuts, since the cut stringer is never longer than that line. Past 16 ft, the stair needs a landing or a post partway down.

Bottom riser. The first riser on the stringer is cut shorter by one tread thickness: 1.5 in for 2x6 treads and 1 in for 5/4 and composite. Once the treads go on, the first step comes out the same height as the rest.

Stringers. The stair width is divided by the spacing and rounded up, plus one, so there is a stringer at each side. DCA 6 asks for at least 3 cut stringers, so a narrow stair still gets 3.

Tread boards. Each step takes enough 5.5 in boards, with a gap between them, to cover the run plus the nosing. Pieces are cut to the stair width, and each stock board gives as many whole pieces as fit in its length.

Comfort and strength. Twice the riser plus the run (2R + T) between 24 and 25 in feels natural to walk; it is a rule of thumb from indoor stairs, so the result shows it as a note.

Deck stair limits at a glance

What Value
Riser, IRC maximum 7 3/4 in
Run per step, IRC minimum 10 in, nose to nose
Riser and tread difference in one flight 3/8 in at most
Nosing, runs under 11 in 3/4 to 1 1/4 in
Stair width 36 in clear at least
Headroom 6 ft 8 in
Open risers, rise over 30 in gap under 4 in
Cut 2x12 stringer, longest run 6 ft
Wood under each notch 5 in at least
Cut stringers 3 at least
Stringer spacing, 2x wood treads 16 in, 18 in at most
Stringer spacing, 5/4 wood treads 12 in
Stringer spacing, composite 9 in here, check the brand
Handrail 4 or more risers
Landing at the foot 36 in deep, solid

These limits come from the IRC and the AWC’s DCA 6 deck guide, and your town may be stricter. A flight of 4 or more risers needs a handrail, and an open side more than 30 in above the ground needs a guard, so ask your building department. The calculator shows a warning under the result for each limit your stair misses and never changes the count to fit.

What the stair calculator leaves out (landings, handrails, footings)

This page counts materials. It is not a structural design, and your local code decides what is allowed. Landings, handrails and guards, footings, stringer hangers, spiral and winder stairs, indoor stairs, solid riser boards and prices are not counted here. No span table is given as an answer, because your code sets those for your site.

Worked example

  1. Risers: 44 in ÷ 7 in = 6.29, round up to 7 risers
  2. Riser height: 44 in ÷ 7 = 6.286 in, about 6 5/16 in
  3. Treads: 7 risers − 1 = 6 treads (the deck is the top step)
  4. Total run: 6 treads × 10.5 in = 63 in
  5. Stringer length: √(44² + 63²) = 76.84 in, so an 8 ft 2x12 (96 in, 19.16 in to spare)
  6. Bottom riser: 6.286 in − 1.5 in tread = 4.786 in, about 4 13/16 in
  7. Angle: atan(6.286 ÷ 10.5) = 30.9°
  8. Stringers: 36 in ÷ 16 in = 2.25, round up to 3 spaces + 1 = 4 stringers (3 at least)
  9. Boards per step: (10.5 in run + 0.75 in nosing + 0.25 in gap) ÷ (5.5 in board + 0.25 in gap) = 2, so 2 boards
  10. Tread boards: 2 per step × 6 treads = 12 pieces of 36 in; a 12 ft board cuts 4, so 12 ÷ 4 = 3 boards
  11. Comfort: 2 × 6.286 in + 10.5 in = 23.07 in
  12. Wood under each notch: 11.25 in − 6.286 × 10.5 ÷ √(6.286² + 10.5²) = 5.86 in

Questions people ask

How many steps do I need for a deck 44 inches high?

7 risers of 6.286 in each. Divide the height by the riser you want and round up: at a 7 in target, 44 ÷ 7 = 6.29, so 7. With the deck as the top step, that is 6 treads.

What is the throat of a stair stringer?

5 in at least: the solid wood left under each notch, measured square to the edge of the 2x12 (AWC DCA 6 shows this). Cut it from a 2x12; the 44 in example leaves 5.86 in.

How long a 2x12 do I need for a stair stringer?

A 44 in rise with 63 in of run gives 76.84 in, so an 8 ft 2x12 with 19.16 in to spare: take the square root of the rise squared plus the total run squared. Some guides add 6 in for the end cuts, but the cut stringer never needs more than this line, so the calculator buys the shortest board that covers it.

How far apart should deck stair stringers be?

Wood 2x treads: 16 in apart in most guides, and DCA 6 caps cut stringers at 18 in. 5/4 wood treads: 12 in. Composite: 9 in here, which Trex Enhance and Deckorators ask for; check your brand. Use 3 cut stringers at least.

What are the code limits for deck stairs?

The IRC allows a riser of 7 3/4 in at most and a run of 10 in at least, with no riser or tread more than 3/8 in different from the others. The stair must be 36 in wide at least, and a run under 11 in needs a nosing of 3/4 to 1 1/4 in. Your town can be stricter, so check your local building code.

Do I need closed risers on deck stairs?

Open risers are fine if the gap under each tread stops a 4 in ball, and that limit only applies when the total rise is more than 30 in. In the example the gap is 4.786 in on a 44 in rise, so close the risers or add a riser board.