Insulation Calculator
Blown-in bags and depth, or batt packs, from makers' charts.
Owens Corning AttiCat (27.5 lb bag): 25 bags per 1,000 sq ft of attic for R-49, blown 17 in deep.
Length x width of the attic floor: a 30 x 40 ft attic is 1,200 sq ft. Use the top floor's ceiling only, not the house's total floor area or the roof area.
Each bag covers a different area: the chart printed on your bag is the one that counts.
From your bag's chart, at the row for the R-value to add or the next row up.
The chart's minimum installed thickness for that row.
Optional. Printed on the bag; it gives the weight.
ENERGY STAR's levels for existing homes. Your local building code may ask for more.
Old and new insulation together.
Measure from the ceiling drywall up to the top, in a few places. 0 = none. Gray-brown, pea-size granules may be vermiculite, which can contain asbestos: leave it alone until an approved lab has tested it.
2.5 R per inch (DOE)
Center to center of the studs or joists.
15 x 93 in pieces
Read it on the package. Owens Corning 10, 11 or 13; Knauf 12.
Printed on the package or the roll.
Optional. The chart's count is already the minimum for the R-value.
Type your price to see the cost.
- R-49 is a row on the AttiCat chart: 25 bags per 1,000 sq ft, at least 17 in deep.
- Owens Corning, Knauf and Greenfiber all ask for both: the bag count and the depth. Fewer bags or a thinner layer gives a lower R-value.
- Before you blow: keep insulation 3 in away from recessed lights that are not IC rated, out of the air space around flues and chimneys, and off the soffit vents (fit baffles).
- Wear safety glasses, gloves and an N95 dust mask, and walk only on the joists.
- Owens Corning chart: May 2026. The chart printed on your bag is the one that counts; a Minnesota column on it adds inches and bags.
This counts bags, depth and packages from the makers' charts, not heat loss, ventilation or code compliance. Your local building code comes first.
- Blown-in insulation
- Attic floor area: 1200 sq ft
- Bag: Owens Corning AttiCat (27.5 lb)
- Target: R-49
- There now: 0 in of loose fiberglass
Bags per 1,000 sq ft and depth at R-19 to R-60, by maker
| R-value | AttiCat (27.5 lb) | Jet Stream ULTRA (32 lb) | SANCTUARY (25 lb) |
|---|---|---|---|
| R-19 | 9 bags · 7 in | 8.4 bags · 6.75 in | 22.6 bags · 5.7 in |
| R-30 | 14.6 bags · 10.75 in | 13.6 bags · 10.375 in | 38.6 bags · 8.9 in |
| R-38 | 19 bags · 13.5 in | 17.8 bags · 13 in | 52.6 bags · 11.2 in |
| R-49 | 25 bags · 17 in | 23.5 bags · 16.375 in | 70.8 bags · 14.3 in |
| R-60 | 31.5 bags · 20.5 in | 29.7 bags · 19.75 in | 86 bags · 17.3 in |
Between two rows, the calculator uses the next row up.
A 1,200 sq ft attic with no insulation now needs 30 bags of Owens Corning AttiCat (27.5 lb) to reach R-49, blown 17 in deep.
How to use the insulation calculator
The calculator returns bags and the depth to blow for loose fill on an attic floor, or packs for batts and rolls in walls, attic joists and floors: pick which you are installing. For blown-in, enter the attic floor area, length times width, from the top floor’s ceiling only: not the house’s total floor area, and not the roof. For walls, use the wall length times its height minus windows and doors, which the siding calculator works out. To count the studs that set the batt width, use the stud calculator.
Pick the climate zone or type your own target, enter what is in the attic now and its type, and pick your bag (or “Other bag” to type its chart). The result shows the R-value you land on. For batts, pick the spacing and R-value, and read the pieces per package off the package.
How many bags of blown-in insulation you need, and how deep
Multiply the attic floor area by the bag chart’s bags per 1,000 sq ft for the R-value you add, then round up: 1,200 sq ft at R-49 takes 1,200 x 25 ÷ 1,000 = 30 bags of AttiCat. Owens Corning, Knauf and Greenfiber require both the bag count and the minimum depth, so the page gives both.
Charts list set R-values, so between two rows the calculator uses the next row up and you land a little above target. The charts count net attic floor with no allowance for joists; with 2x6 joists 16 in apart, the makers’ framing columns take about 5 percent fewer bags (Knauf R-30: 12.9 instead of 13.6), so your count has a little spare. Staple attic rulers to the joists to mark the depth (Owens Corning: one per 300 sq ft).
Attic insulation: what R-value to aim for by climate zone
ENERGY STAR recommends R-30 for an uninsulated attic in climate zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 to 8, based on the 2021 IECC. R-value is how well a layer resists heat flow. That level is the total, so with insulation already there the calculator subtracts it.
Floors over unheated space need R-13 in zones 1 and 2, R-19 in zone 3 and zones 4A and 4B, R-30 in zones 4C to 6, and R-38 in zones 7 and 8. Find your zone on ENERGY STAR’s R-value page or in DOE’s county guide under Sources. These are recommendations for existing homes, not a code: your local building code may ask for more, so check it.
Batts and rolls: 15 or 23 inch, and what fits a 2x4 or 2x6 wall
Buy 15 in batts for studs 16 in on center and 23 in batts for studs 24 in on center: the gap between 1 1/2 in studs is 14 1/2 or 22 1/2 in, and batts are made a little wider so they hold by friction. “On center” is measured from the middle of one stud to the next.
A 2x4 wall is 3 1/2 in deep, so R-13 or R-15 fills it. A 2x6 wall is 5 1/2 in deep: R-21 fills it, while R-19 at 6 1/4 in is squeezed and gives about R-18, Knauf says. Never fold or cram a batt (Owens Corning, DOE). Attic R-30 and R-38 come 16 or 24 in wide and unfaced. For rolls and other packs, pick “Other” and type the square feet on the package.
Before you blow insulation: recessed lights, flues, soffit vents, old wiring
Keep insulation at least 3 in from recessed lights and never cover them unless they are IC rated for contact with insulation, because a covered light can overheat (Owens Corning, Greenfiber). Keep it out of the air space around metal flues and chimneys; Greenfiber asks for a barrier at least 3 in from any heat source, so check your local code. Fit baffles so insulation never blocks soffit vents.
With knob-and-tube wiring, DOE notes the National Electrical Code bars loose or rolled insulation around it, so have an electrician check it. Walk on the joists, and wear safety glasses, gloves and a dust mask. Vermiculite, light gray-brown pea-size granules, may contain asbestos: leave it alone until a lab has tested it.
What the insulation estimate leaves out: wall blowing, spray foam, air sealing
Blowing closed walls is a contractor job: the AttiCat machine is not made for enclosed cavities (Owens Corning), and Knauf allows it only by certified installers. Spray and rigid foam, ventilation sizing and energy savings are not counted. ENERGY STAR asks you to seal attic air leaks first. The AttiCat chart has a separate Minnesota column that adds inches and bags: use it if you live there.
Worked example
- Insulation there now: 0 in, so R-0
- R-value to add: R-49 target − R-0 = R-49
- Chart row: R-49 on the AttiCat chart, the first row at or above R-49: 25 bags per 1,000 sq ft, at least 17 in deep
- Bags: 1,200 sq ft × 25 ÷ 1,000 = 30, rounded up: 30 bags
- Weight: 30 bags × 27.5 lb = 825 lb (374.2 kg)
- R-value reached: R-0 + R-49 = R-49
Questions people ask
How many bags of blown-in insulation do I need for 1,000 sq ft?
25 bags of Owens Corning AttiCat (27.5 lb) reach R-49 on a bare attic floor, blown 17 in deep. Knauf Jet Stream ULTRA (32 lb) needs 23.5 and Greenfiber SANCTUARY cellulose (25 lb) 70.8, because each bag weighs and fluffs differently. Buy by the chart printed on your bag.
How many inches of blown-in insulation is R-38?
13.5 in of AttiCat, 13 in of Jet Stream ULTRA, or 11.2 in of SANCTUARY cellulose as blown, which settles to 10.4 in. R-49 takes 17, 16 3/8 and 14.3 in. The makers ask for both the bag count and this depth.
How do I find the R-value of the insulation I already have?
Multiply its depth in inches by 2.5 for loose fiberglass, 3.7 for cellulose, 2.8 for rock wool or 3.2 for fiberglass batts: 6 in of loose fiberglass is about R-15. These are DOE's rules of thumb, so treat the result as an estimate.
Can I blow new insulation on top of old?
Yes: add only the difference, so 6 in of fiberglass batts (about R-19) plus 5.7 in of SANCTUARY cellulose (R-19 more) reaches R-38, Greenfiber's example. Use no vapor barrier between the layers, and remove insulation that is wet or moldy first.
Does blown-in insulation settle?
Cellulose does: SANCTUARY blown 14.3 in deep settles to 13.3 in, and its R-49 is for the settled depth. Knauf says Jet Stream ULTRA settles 1 percent or less over 20 years, and the AttiCat chart lists the same installed and settled depth. Blow to the installed figure.