Studs = wall length / spacing, rounded up, plus 1: a 12 ft wall at 16 in takes 10, before corners and openings.

Add each wall as its own row, measured along the outside. A corner is where two rows meet.

Your plans or local code say which spacing a wall may use.

Count each place two walls meet once. A closed box of 4 walls has 4.

Where an inside wall meets another wall. Add the inside wall as a row too.

From the door's install sheet. A 36 in prehung door needs about 38 in.

From the window maker's size chart. Different sizes? Type the widest.

Same count. Sets the plates, sills and board feet.

Optional. Blank adds no extra studs.

Optional. Blank leaves the cost out.

Studs

62studs

46 along the walls + 4 at corners + 12 at doors and windows

Stud length

92 5/8in

Precut 2x4 studs for an 8 ft ceiling (97 1/8 in wall)

Plates

11plate boards

2x4 x 16 ft for 168 ft of plate: 1 row on the bottom, 2 on top

Order 62 precut 2x4 studs (92 5/8 in), 11 2x4s 16 ft long for plates, and header boards for 3 openings.
  • Which walls carry weight, header sizes and how many jack studs an opening needs come from your plans or local code. Work on a load-bearing wall needs a permit in many places, even a small job: ask your building department.
  • Headers: 2 pieces 41 in long for the door and 2 pieces 39 in long for each window (6 pieces). The header size comes from your plans or local code.
  • Sills: 2 pieces of 2x4, 36 in long, one under each window.
  • Cripples above the headers and under the sills are cut from the studs that fall inside the openings, so they add no studs.
  • Lumber: 440.4 board feet of studs, plates and sills (headers not included).

Studs for one straight wall at 12, 16 and 24 in on center

Wall studs only: add corners, T-walls, doors and windows above.
Wall length12 in on center16 in on center24 in on center
8 ft975
10 ft1196
12 ft13107
14 ft15128
16 ft17139
20 ft211611

Precut stud lengths and framed wall heights

Precut studs on one bottom plate and two top plates, 1 1/2 in each.
CeilingPrecut studFramed wall height
8 ft92 5/8 in97 1/8 in
9 ft104 5/8 in109 1/8 in
10 ft116 5/8 in121 1/8 in

56 ft of wall, 8 ft high, with 4 corners, 1 door and 2 windows at 16 in on center takes 62 studs (92 5/8 in precut) and 11 plate boards 16 ft long.

How to use the stud calculator

  1. Add each wall as a row, measured along the outside: a 12 x 16 ft shed is 12, 16, 12 and 16.
  2. Pick the spacing and wall height, or Other to type the framed height.
  3. Count corners, where two rows meet, and T-walls, where an inside wall meets another.
  4. Type the doors and windows with their rough openings.
  5. Pick 2x4 or 2x6 and the plate board length; extra studs and prices are optional.
  6. For the wall sheathing, use the plywood calculator.

How many studs for a wall: length ÷ spacing, round up, add 1

A 12 ft wall at 16 in on center takes 10 studs: 144 in ÷ 16 in = 9 spaces, plus 1 for the end stud. The last stud stands at the far end even when the last space comes up short (Making Manzanita): a 10 ft wall takes 9 studs, the last space 8 in. That is about 3 studs per 4 ft of wall. The board foot calculator turns the 2x4s into board feet.

Framing calculator: corners, T-walls, doors and windows

A framing takeoff adds 1 stud per standard corner, 2 per standard T-wall and 4 per door or window: a full-height king stud and a shorter jack stud, which holds up the header over the opening, on each side. One jack stud a side is common for smaller openings; wider or more heavily loaded openings can need two and a bigger header. Header size and the number of jack studs come from your plans or local code.

Cripples, the short studs above the header and under a window’s sill, come from the studs that fell inside the opening, so nothing comes off.

A standard 3-stud corner adds 1 to the two wall ends; a 2-stud corner, with drywall clips or blocking, adds none (US DOE, Green Building Advisor). A standard T-wall’s 3 studs include the partition’s end stud, so it adds 2; ladder blocking drops them.

How far apart are studs? 16 or 24 inches on center

Most walls are framed 16 in on center; advanced framing uses 24 in, and heavy-load walls 12 in. On center is measured from the middle of one stud to the next. ArchitectureCourses.org keeps 24 in to 2x6 outside walls and walls that carry no load. Your plans or local code say which spacing a wall may use. 16 and 24 in both divide a 4 x 8 ft sheet, so sheathing edges land on a stud.

Stud length: 92 5/8 in precut studs make an 8 ft wall

A 92 5/8 in stud on one bottom plate and two top plates, 1 1/2 in each, makes a 97 1/8 in wall, so an 8 ft ceiling clears with room for drywall (Hansen Pole Buildings). Precuts of 104 5/8 and 116 5/8 in do the same for 9 and 10 ft ceilings; Weyerhaeuser sells them as available, so ask your yard which it stocks. For a taller wall, pick Other: the calculator takes 4 1/2 in off the framed height and picks the shortest precut or 8 to 16 ft board that covers it.

Plates, headers and sills for the wall

A wall takes 3 ft of plate per foot of wall: one bottom plate and a double top plate. All the rows’ plate is divided by the board length once: the 12 x 16 ft shed’s 168 ft makes 11 boards 16 ft long. The top plates overlap at corners and where bearing walls meet: check your local code for the lap. Many codes allow one top plate on interior walls that carry no load; this count keeps two.

Each header is the rough opening plus 3 in, one 1 1/2 in jack stud at each end, from 2 boards, and each window gets a sill as long as its rough opening. The plywood calculator counts the sheathing.

What the stud count leaves out: header sizes, sheathing, nails

It leaves out header sizes, sheathing, drywall, nails, insulation, steel studs, gable-end studs and openings over 72 in. Which walls carry weight, header sizes and how many jack studs an opening needs come from your plans or local code. Work on a load-bearing wall needs a permit in many places, even a small job: ask your building department.

Worked example

  1. Wall 1: 144 in ÷ 16 in = 9 spaces, + 1 = 10 studs
  2. Wall 2: 192 in ÷ 16 in = 12 spaces, + 1 = 13 studs
  3. Wall 3: 144 in ÷ 16 in = 9 spaces, + 1 = 10 studs
  4. Wall 4: 192 in ÷ 16 in = 12 spaces, + 1 = 13 studs
  5. Along the walls: 10 + 13 + 10 + 13 = 46 studs
  6. Corners: 4 × 1 extra stud for a 3-stud corner = 4
  7. Doors and windows: (1 + 2) × 4, a king and a jack stud on each side = 12
  8. Studs: 46 + 4 + 12 = 62
  9. Stud length: 97.125 in wall − 4.5 in of plates (3 × 1.5 in) = 92.625 in, so 92 5/8 in precut studs
  10. Plates: 3 rows × 56 ft = 168 ft ÷ 16 ft = 10.5, rounded up to 11 boards
  11. Headers: 38 + 3 = 41 in for the door, 36 + 3 = 39 in for each window; 2 pieces per opening = 6 pieces
  12. Board feet: 2 × 4 in × (62 × 92.625 + 11 × 192 + 2 × 36 in) = 63,414 cu in ÷ 144 = 440.4

Questions people ask

How many 2x4s do I need to frame a wall?

10 studs and 3 plate boards for a plain 12 ft wall at 16 in on center: 144 in ÷ 16 in = 9 spaces plus 1, and 36 ft of plate makes three 16 ft boards. Corners, doors and windows add more.

How many studs for a 12 x 16 shed?

62 at 16 in on center with 3-stud corners, 1 door and 2 windows: 46 along the walls, 4 at the corners and 12 at the openings, all 92 5/8 in precut studs for an 8 ft ceiling.

How many studs does a corner need?

3 at a standard corner and 2 with advanced framing, which holds the drywall with clips or blocking. Each wall already ends in a stud, so a standard corner adds 1 and a 2-stud corner adds none.

Does a window or door change the stud count?

Yes, 4 more per opening: a king stud and a jack stud on each side. None come off: the studs inside the opening become cripples.

What rough opening does a 36 inch door need?

About 38 in wide: RESO's interior prehung sheet lists 38 in and Masonite's entry door sheet 38 1/4 in. Use your door's install sheet; the header is that opening plus 3 in.

Related calculators